Tip: How to distinguish between real - and nominal bar diameter.

To modify the default value of the parameter Model Bar Diameter, select rebar > Properties palette > Click icon_EditType (Edit Type) > Dimensions > Change the value of Model Bar Diameter.

Note

The changes to type properties will be applied to all instances in the project

SOFiSTiK Reinforcement Detailing tools will use the parameter Model Bar Diameter for any representation and clash control purposes. The parameter Bar Diameter (nominal) will be used for any annotation and scheduling purposes.