BE35: Calculation of Restraining Forces in Steel Members in case of Fire

This benchmark is concerned with the validation of the structural analysis in case of fire with respect to the general calculation method according to DIN EN 1992-1-2. Therefore test case 7 is employed as presented in Annex CC of the standard DIN EN 1992-1-2/NA:2010-03 [35]. In this example the restraining forces developed in an immovable steel member due to temperature exposure are investigated for
the model of the figure.This is one example of our Verification Manual. You can find the whole manual in SSD and TEDDY via menue Help > Verification Manual, the input data files in TEDDY via menue Help> examples... > verification.

Typ Benchmark Beispiel
Produktgruppe Statik / Dynamik / FEM
Anwendung Allgemein
Datum 27.06.2014
Keywords Benchmark example, quality assurance